Picture Name

new energy products

Supported by source-network-load-storage interaction and multi-energy complementarity, Longitudinal Power provides 35kV step-up transformer, energy storage and step-up integrated machine, inverter and step-up integrated machine, 100kW/215kWh distributed energy storage complete set, 100kW/215kWh industrial and commercial air-cooled energy storage complete set, 100kW/215kWh industrial and commercial liquid-cooled energy storage complete set, 15kW optical storage microgrid complete set, centralized large-scale energy storage system and other key new energy equipment.

35kV step-up transformer
+
  • 35kV step-up transformer

35kV step-up transformer


35kV step-up transformer winding adopts high conductivity copper conductor, high and low voltage are all copper windings. The iron core adopts domestic high-quality high-permeability oriented silicon steel sheet, the iron core is firmly bound and clamped, and has good insulation. All fasteners are treated with anti-loosening. The transformer body adopts a new insulation structure, and the transformer has strong short-circuit resistance. The transformer is equipped with a temperature controller. In addition to displaying the three-phase winding temperature during operation, it also has control functions such as fault alarm, high temperature sound and light alarm, and overtemperature trip alarm. The product is equipped with a fan, which can effectively protect the safe operation of the transformer.

Product Parameters

Performance characteristics

1. Low loss, energy saving and environmental protection.

2. Good technical and economic performance.

3. Low noise.

4. High efficiency and energy saving, can save a lot of power consumption and operating costs, social benefits are significant.

5. Good moisture-proof performance, fire retardant, no pollution, maintenance-free, easy to install.

 

 

Technical parameters

 

Transformer model

Capacity

HV kV

High voltage tap range

Low pressure
kV

Linkage

Group Label

Core Material

Rated frequency Hz

Phase number

Cooling mode

Insulation heat resistance grade

S11
S13
S18

S18-NX3
S20
S20-NX2
S22
S22-NX1

50~ 10000

35
36.5
37
38.5

±5
± 2 × 2.5

0.55
0.6
0.63
0.69

0.8

1.14

Dy11

cold rolled oriented silicon wafer

50

3

Natural cooling

A

SCB10

SCB11

SCB12

SCB12-NX3

SCB13

SCB14

SCB14-NX2

SCB18

SCB18-NX1

50~ 4000

35
36.5
37
38.5

± 2 × 2.5

0.55
0.6
0.63
0.69

0.8

1.14

Dy11

cold rolled grain oriented silicon steel

50

3

AN

AF

Class F and above

Message

* Note: Please fill in the information accurately and keep communication smooth. We will contact you as soon as possible.

Submission