Supported by source-network-load-storage interaction and multi-energy complementarity, Longitudinal Power provides 35kV step-up transformer, energy storage and step-up integrated machine, inverter and step-up integrated machine, 100kW/215kWh distributed energy storage complete set, 100kW/215kWh industrial and commercial air-cooled energy storage complete set, 100kW/215kWh industrial and commercial liquid-cooled energy storage complete set, 15kW optical storage microgrid complete set, centralized large-scale energy storage system and other key new energy equipment.

35kV step-up transformer
+
  • 35kV step-up transformer

35kV step-up transformer


The winding of the 35kV step-up transformer adopts high conductivity copper conductors, and the high and low voltage are all copper windings. The iron core is made of high-quality domestic high magnetic orientation silicon steel sheets. The iron core is firmly tied and clamped, with good insulation. All fasteners are treated with anti loosening, and the transformer body adopts a new insulation structure. The transformer has strong short-circuit resistance. The transformer is equipped with a temperature controller, which not only displays the temperature of the three-phase winding during operation, but also has control functions such as fault alarm, high temperature sound and light alarm, and over temperature trip alarm. The product is equipped with a fan, which can effectively protect the safe operation of the transformer.

Product Parameters

Performance characteristics

1. Low loss, energy-saving and environmentally friendly.

2. Good technical and economic performance.

3. Low noise.

4. Efficient and energy-saving, which can save a lot of electricity consumption and operating costs, and has significant social benefits.

5. Good moisture-proof performance, flame retardant, pollution-free, maintenance free, and convenient installation.

 

 

Technical parameters

model

capacity

HV

kV

HV tapping range

LV
kV

connection symbol

Iron core material

Rated frequency

Hz

Phase number

Cooling method

Insulation Class

S11
S13
S18

S18-NX3
S20
S20-NX2
S22
S22-NX1

50~ 10000

35
36.5
37
38.5

±5
±2×2.5

0.55
0.6
0.63
0.69

0.8

1.14

Dy11

Cold rolled oriented silicon wafers

50

3

Natural cooling

A

SCB10

SCB11

SCB12

SCB12-NX3

SCB13

SCB14

SCB14-NX2

SCB18

SCB18-NX1

50~ 4000

35
36.5
37
38.5

±2×2.5

0.55
0.6
0.63
0.69

0.8

1.14

Dy11

Cold rolled oriented silicon wafers

50

3

AN

AF

F level and above